  "entityType": "generator",
  "id": "champion-201412",
  "canonicalUrl": "https://agentretrievalindex.com/generators/champion-201412/",
  "jsonUrl": "https://agentretrievalindex.com/generators/champion-201412.json",
  "name": "Champion 201412 Tri Fuel",
  "brand": "Champion",
  "category": {
    "id": "portable-generators",
    "name": "Portable Generators",
    "canonicalUrl": "https://agentretrievalindex.com/categories/portable-generators/",
    "jsonUrl": "https://agentretrievalindex.com/categories/portable-generators.json"
  },
  "summary": "Tri-fuel home-backup workhorse: 9,200 W running / 11,500 W starting on gasoline (8,500/10,625 W propane, 7,500/9,375 W natural gas), 120/240 V with L14-30R and 14-50R outlets, GFCI 120 V outlets, CO Shield shutdown, and 10 h at 50% load on the 8.5 gal tank.",
  "description": "Champion's 201412 runs on gasoline, propane, or natural gas — with per-fuel running and starting watts published in the manual's spec tables and stored separately here. Its 459 cc engine feeds a 120/240 V panel: an L14-30R locking outlet, a 14-50R that Champion rates at 38 A (not 50 A — worth knowing before buying a cord), and four GFCI-protected 120 V household outlets. Electric start with included battery, CO Shield automatic shutdown (whose manual explicitly notes it is not a substitute for an indoor CO alarm — and never permits indoor use), and a 25-ft natural gas hose kit in the box. Runtime: 10 h at 50% load on gasoline, 5 h at 50% on a 20-lb propane tank; natural gas runtime is supply-line dependent and unpublished. THD is not stated — this conventional AVR unit is not flagged for sensitive electronics.",
  "identity": {
    "brand": "Champion",
    "modelName": "201412 (9200W Electric Start Tri Fuel with CO Shield)",
    "normalizedSlug": "champion-201412",
    "seriesFamily": "Tri Fuel conventional",
    "releaseStatus": "current",
    "marketRegion": [
      "US"
    ],
    "officialProductUrl": "https://www.championpowerequipment.com/product/201412-9200w-electric-start-tri-fuel-generator-with-co-shield/",
    "officialManualUrl": "https://www.championpowerequipment.com/wp-content/uploads/2024/03/201412-om-english.pdf"
  },
  "typeAndFuel": {
    "generatorType": "conventional_portable",
    "inverterTechnology": false,
    "frameType": "open_frame",
    "fuelType": "gasoline",
    "supportedFuelTypes": [
      "gasoline",
      "propane",
      "natural_gas"
    ],
    "fuelTankCapacityGal": 8.5,
    "propaneSupport": true,
    "naturalGasSupport": true,
    "electricStart": true,
    "recoilStart": true,
    "remoteStart": false,
    "parallelCapable": false
  },
  "output": {
    "runningWatts": 9200,
    "startingWatts": 11500,
    "runningWattsByFuel": {
      "gasoline": 9200,
      "propane": 8500,
      "natural_gas": 7500
    },
    "startingWattsByFuel": {
      "gasoline": 11500,
      "propane": 10625,
      "natural_gas": 9375
    },
    "voltage": "120/240V",
    "frequency": "60Hz",
    "totalHarmonicDistortion": null,
    "receptacleSummary": {
      "5-20R": {
        "count": 4,
        "note": "two GFCI duplexes (four outlets), 120V 20A"
      },
      "L14-30R": {
        "count": 1,
        "note": "120/240V 30A locking"
      },
      "14-50R": {
        "count": 1,
        "note": "120/240V — rated 38A by Champion, not 50A"
      }
    },
    "rvOutletPresent": false,
    "tt30Present": false,
    "l1430Present": true,
    "v240Support": true
  },
  "runtimeAndOperating": {
    "runtimeAt25LoadHours": null,
    "runtimeAt50LoadHours": 10,
    "runtimeByFuelAndLoad": {
      "gasoline": {
        "50": 10
      },
      "propane": {
        "50": 5
      }
    },
    "noiseDb": {
      "unknown_basis": 74
    },
    "engineSizeCc": 459,
    "fuelConsumptionNotes": "Propane runtime (5 h at 50%) is on a 20-lb tank. Natural gas runtime not published; NG operation requires a dedicated supply line sized to the manual's minimum flow table (25-ft NG hose kit included). Noise: 74 dBA from 23 ft, load basis not stated."
  },
  "safetyAndCompliance": {
    "coShutdown": "present",
    "coSensorBranding": "CO Shield",
    "lowOilShutdown": true,
    "overloadProtection": true,
    "gfciOutlets": true,
    "coveredOutlets": true,
    "epaCertified": true,
    "carbCompliant": null,
    "csaEtlListing": null,
    "pgmaCompliant": true,
    "indoorUse": "NEVER — fuel generators are outdoor-only; see manufacturer safety instructions"
  },
  "physical": {
    "weightKg": 99.5,
    "dimensionsMm": {
      "l": 730,
      "w": 698,
      "h": 662
    },
    "wheelKitIncluded": true,
    "handleStyle": null
  },
  "crossCategory": {
    "indoorSafe": false,
    "fumesPresent": true,
    "noiseClass": "unknown",
    "fuelDependency": "fuel_required",
    "refillableRuntimeAdvantage": "strong",
    "sensitiveElectronicsSuitability": "low",
    "apartmentSuitable": "no",
    "rvSuitable": false,
    "campingSuitable": false,
    "homeBackupSuitable": true
  },
  "derived": {
    "wattsPerKg": 92.5,
    "runtimePerGallonAt50LoadHours": 1.2,
    "portabilityBand": "heavy",
    "_meta": {
      "sourceType": "derived_metric",
      "assumptions": "wattsPerKg = runningWatts / weightKg. runtimePerGallonAt50LoadHours = runtimeAt50LoadHours / fuelTankCapacityGal (gasoline tank, null when either input is unpublished). portabilityBand from weight and frame type (compact: ≤25 kg suitcase; mid: ≤60 kg; heavy: >60 kg). Derived values never override official specs."
    }
  },
  "metadata": {
    "sourceUrls": [
      "https://www.championpowerequipment.com/product/201412-9200w-electric-start-tri-fuel-generator-with-co-shield/",
      "https://www.championpowerequipment.com/wp-content/uploads/2024/03/201412-om-english.pdf"
    ],
    "sourceLastChecked": "2026-07-08",
    "confidenceLevel": "medium",
    "notes": "Weight conflict between official sources (manual '219 lb. (99.5 kg)' vs page '216 lb.'); manual value used, both preserved. Champion rates the 14-50R at 38 A — recorded exactly, since buyers assume 50 A from the receptacle form. Natural-gas runtime unpublished (supply-line dependent). THD not stated anywhere official; conventional AVR unit → sensitive-electronics suitability low. Noise (74 dBA from 23 ft) lacks a load basis → stored unknown_basis, noiseClass unknown. CARB and CSA/ETL not stated (null). Grounding: neutral bonded to frame. pgmaCompliant=true per PGMA G300-2018 reference in the manual.",
    "variantNotes": "Selected as the best-documented 8,500 W+-class tri-fuel conventional with both L14-30R and 14-50R. Related tri-fuel models (separate entities): 201176 (9,000 W open-frame inverter), 201438 (10,000 W), 201161 (12,000 W with true 50 A 14-50R), 201241 (13,500 W), 201121 (8,000 W).",
    "revisionNotes": null
  },
  "provenance": [
    {
      "fieldName": "runningWatts",
      "normalizedValue": 9200,
      "rawClaimText": "Watts (Starting/Running).............................. 11500/9200",
      "sourceUrl": "https://www.championpowerequipment.com/wp-content/uploads/2024/03/201412-om-english.pdf",
      "sourceType": "official_manual_pdf",
      "dateChecked": "2026-07-08",
      "confidence": "high",
      "notes": "Gasoline figures; page matches."
    },
    {
      "fieldName": "startingWatts",
      "normalizedValue": 11500,
      "rawClaimText": "Watts (Starting/Running).............................. 11500/9200",
      "sourceUrl": "https://www.championpowerequipment.com/wp-content/uploads/2024/03/201412-om-english.pdf",
      "sourceType": "official_manual_pdf",
      "dateChecked": "2026-07-08",
      "confidence": "high",
      "notes": ""
    },
    {
      "fieldName": "runningWattsByFuel",
      "normalizedValue": {
        "gasoline": 9200,
        "propane": 8500,
        "natural_gas": 7500
      },
      "rawClaimText": "Watts (LPG) (Starting/Running)........................ 10625/8500 ... Watts (NG) (Starting/Running)........................... 9375/7500",
      "sourceUrl": "https://www.championpowerequipment.com/wp-content/uploads/2024/03/201412-om-english.pdf",
      "sourceType": "official_manual_pdf",
      "dateChecked": "2026-07-08",
      "confidence": "high",
      "notes": "All three fuels numerically published in the manual spec table."
    },
    {
      "fieldName": "startingWattsByFuel",
      "normalizedValue": {
        "gasoline": 11500,
        "propane": 10625,
        "natural_gas": 9375
      },
      "rawClaimText": "Watts (LPG) (Starting/Running)........................ 10625/8500 ... Watts (NG) (Starting/Running)........................... 9375/7500",
      "sourceUrl": "https://www.championpowerequipment.com/wp-content/uploads/2024/03/201412-om-english.pdf",
      "sourceType": "official_manual_pdf",
      "dateChecked": "2026-07-08",
      "confidence": "high",
      "notes": ""
    },
    {
      "fieldName": "voltage",
      "normalizedValue": "120/240V",
      "rawClaimText": "Volts AC...................................................... 120/240 ... Frequency ...................................................... 60 Hz",
      "sourceUrl": "https://www.championpowerequipment.com/wp-content/uploads/2024/03/201412-om-english.pdf",
      "sourceType": "official_manual_pdf",
      "dateChecked": "2026-07-08",
      "confidence": "high",
      "notes": "Gasoline AC amps: 76.7A @ 120V, 38.3A @ 240V per manual."
    },
    {
      "fieldName": "receptacleSummary",
      "normalizedValue": {
        "5-20R": 4,
        "L14-30R": 1,
        "14-50R": 1
      },
      "rawClaimText": "120/240V AC, 30A Locking (NEMA L14-30R) ... 120/240V AC, 38A (NEMA 14-50R) ... (4x) 120V AC, 20A GFCI (NEMA 5-20R)",
      "sourceUrl": "https://www.championpowerequipment.com/wp-content/uploads/2024/03/201412-om-english.pdf",
      "sourceType": "official_manual_pdf",
      "dateChecked": "2026-07-08",
      "confidence": "high",
      "notes": "Champion rates the 14-50R at 38 A. No TT-30R → rvOutletPresent=false; no DC output."
    },
    {
      "fieldName": "fuelTankCapacityGal",
      "normalizedValue": 8.5,
      "rawClaimText": "Gasoline Capacity................................... 8.5 gal. (31.9 L)",
      "sourceUrl": "https://www.championpowerequipment.com/wp-content/uploads/2024/03/201412-om-english.pdf",
      "sourceType": "official_manual_pdf",
      "dateChecked": "2026-07-08",
      "confidence": "high",
      "notes": ""
    },
    {
      "fieldName": "runtimeAt50LoadHours",
      "normalizedValue": 10,
      "rawClaimText": "will run for 10 hours at 50% load when the 8.5-gallon fuel tank is full",
      "sourceUrl": "https://www.championpowerequipment.com/product/201412-9200w-electric-start-tri-fuel-generator-with-co-shield/",
      "sourceType": "official_product_page",
      "dateChecked": "2026-07-08",
      "confidence": "high",
      "notes": "Propane: 5 h at 50% on a 20-lb tank — stored per-fuel. Natural gas runtime not published. No 25% figures."
    },
    {
      "fieldName": "noiseDb",
      "normalizedValue": {
        "unknown_basis": 74
      },
      "rawClaimText": "74 dB(A) from 23 feet",
      "sourceUrl": "https://www.championpowerequipment.com/product/201412-9200w-electric-start-tri-fuel-generator-with-co-shield/",
      "sourceType": "official_product_page",
      "dateChecked": "2026-07-08",
      "confidence": "medium",
      "notes": "Distance stated but LOAD basis not — stored unknown_basis per policy; noiseClass unknown."
    },
    {
      "fieldName": "coShutdown",
      "normalizedValue": "present",
      "rawClaimText": "CO Shield® technology monitors the accumulation of carbon monoxide (CO)... If CO Shield® detects unsafe elevated levels of CO gas, it automatically shuts off the engine.",
      "sourceUrl": "https://www.championpowerequipment.com/wp-content/uploads/2024/03/201412-om-english.pdf",
      "sourceType": "official_manual_pdf",
      "dateChecked": "2026-07-08",
      "confidence": "high",
      "notes": "Manual also warns: 'CO SHIELD® IS NOT A SUBSTITUTE FOR AN INDOOR CARBON MONOXIDE ALARM OR FOR INDOOR OPERATION.'"
    },
    {
      "fieldName": "pgmaCompliant",
      "normalizedValue": true,
      "rawClaimText": "PGMA G300-2018",
      "sourceUrl": "https://www.championpowerequipment.com/wp-content/uploads/2024/03/201412-om-english.pdf",
      "sourceType": "official_manual_pdf",
      "dateChecked": "2026-07-08",
      "confidence": "high",
      "notes": "Standard reference recorded."
    },
    {
      "fieldName": "weightKg",
      "normalizedValue": 99.5,
      "rawClaimText": "Weight.............................................. 219 lb. (99.5 kg)",
      "sourceUrl": "https://www.championpowerequipment.com/wp-content/uploads/2024/03/201412-om-english.pdf",
      "sourceType": "official_manual_pdf",
      "dateChecked": "2026-07-08",
      "confidence": "medium",
      "notes": "CONFLICT: product page spec table lists '216 lb.' (98.0 kg). Manual value used; both preserved. Ships without oil."
    },
    {
      "fieldName": "dimensionsMm",
      "normalizedValue": {
        "l": 730,
        "w": 698,
        "h": 662
      },
      "rawClaimText": "Length............ 28.7 in. (73.0 cm) / Width ............ 27.5 in. (69.8 cm) / Height............ 26.1 in. (66.2 cm)",
      "sourceUrl": "https://www.championpowerequipment.com/wp-content/uploads/2024/03/201412-om-english.pdf",
      "sourceType": "official_manual_pdf",
      "dateChecked": "2026-07-08",
      "confidence": "high",
      "notes": "Champion's own cm values ×10; page matches."
    },
    {
      "fieldName": "engineSizeCc",
      "normalizedValue": 459,
      "rawClaimText": "Displacement................................................. 459 cc",
      "sourceUrl": "https://www.championpowerequipment.com/wp-content/uploads/2024/03/201412-om-english.pdf",
      "sourceType": "official_manual_pdf",
      "dateChecked": "2026-07-08",
      "confidence": "high",
      "notes": "Engine GB460T-2, 4-stroke OHV, 3,600 rpm."
    },
    {
      "fieldName": "warrantyYears",
      "normalizedValue": 3,
      "rawClaimText": "CHAMPION POWER EQUIPMENT 3 YEAR LIMITED WARRANTY",
      "sourceUrl": "https://www.championpowerequipment.com/wp-content/uploads/2024/03/201412-om-english.pdf",
      "sourceType": "official_manual_pdf",
      "dateChecked": "2026-07-08",
      "confidence": "high",
      "notes": ""
    },
    {
      "fieldName": "lowOilShutdown",
      "normalizedValue": true,
      "rawClaimText": "This engine is equipped with a low oil shut-off and will stop when the oil level in the crankcase falls below the threshold level.",
      "sourceUrl": "https://www.championpowerequipment.com/wp-content/uploads/2024/03/201412-om-english.pdf",
      "sourceType": "official_manual_pdf",
      "dateChecked": "2026-07-08",
      "confidence": "high",
      "notes": ""
    },
    {
      "fieldName": "totalHarmonicDistortion",
      "normalizedValue": null,
      "rawClaimText": "Automatic Voltage Regulation: Yes",
      "sourceUrl": "https://www.championpowerequipment.com/product/201412-9200w-electric-start-tri-fuel-generator-with-co-shield/",
      "sourceType": "official_spec_page",
      "dateChecked": "2026-07-08",
      "confidence": "high",
      "notes": "No THD stated anywhere official; conventional AVR unit — sensitive-electronics suitability set to low."
    }
  ],
  "specs": [
    {
      "key": "running_watts",
      "label": "Running (rated) watts",
      "value": "9,200 W"
    },
    {
      "key": "starting_watts",
      "label": "Starting (peak) watts",
      "value": "11,500 W"
    },
    {
      "key": "running_watts_by_fuel",
      "label": "Running watts by fuel",
      "value": "Gasoline: 9,200 W · Propane (LPG): 8,500 W · Natural gas: 7,500 W"
    },
    {
      "key": "starting_watts_by_fuel",
      "label": "Starting watts by fuel",
      "value": "Gasoline: 11,500 W · Propane (LPG): 10,625 W · Natural gas: 9,375 W"
    },
    {
      "key": "voltage",
      "label": "Voltage",
      "value": "120/240V"
    },
    {
      "key": "frequency",
      "label": "Frequency",
      "value": "60Hz"
    },
    {
      "key": "thd",
      "label": "Total harmonic distortion",
      "value": "Not numerically stated"
    },
    {
      "key": "240v",
      "label": "240V support",
      "value": "Yes"
    },
    {
      "key": "fuel",
      "label": "Fuel",
      "value": "Gasoline + Propane (LPG) + Natural gas"
    },
    {
      "key": "tank",
      "label": "Fuel tank (gasoline)",
      "value": "8.5 gal"
    },
    {
      "key": "runtime_0",
      "label": "Runtime — Gasoline, 50% load",
      "value": "10 h"
    },
    {
      "key": "runtime_1",
      "label": "Runtime — Propane (LPG), 50% load",
      "value": "5 h"
    },
    {
      "key": "fuel_notes",
      "label": "Fuel notes",
      "value": "Propane runtime (5 h at 50%) is on a 20-lb tank. Natural gas runtime not published; NG operation requires a dedicated supply line sized to the manual's minimum flow table (25-ft NG hose kit included). Noise: 74 dBA from 23 ft, load basis not stated."
    },
    {
      "key": "engine_cc",
      "label": "Engine displacement",
      "value": "459 cc"
    },
    {
      "key": "noise",
      "label": "Noise",
      "value": "74 dBA (load basis not stated)"
    },
    {
      "key": "start",
      "label": "Start method",
      "value": "recoil, electric"
    },
    {
      "key": "parallel",
      "label": "Parallel capable",
      "value": "No"
    },
    {
      "key": "inverter",
      "label": "Inverter technology",
      "value": "No"
    },
    {
      "key": "receptacles",
      "label": "Receptacles",
      "value": "4 × 5-20R (two GFCI duplexes (four outlets), 120V 20A), 1 × L14-30R (120/240V 30A locking), 1 × 14-50R (120/240V — rated 38A by Champion, not 50A)"
    },
    {
      "key": "rv_outlet",
      "label": "RV outlet (30A RV receptacle)",
      "value": "No"
    },
    {
      "key": "tt30",
      "label": "TT-30R present",
      "value": "No"
    },
    {
      "key": "l1430",
      "label": "L14-30R present",
      "value": "Yes"
    },
    {
      "key": "gfci",
      "label": "GFCI outlets",
      "value": "Yes"
    },
    {
      "key": "covered",
      "label": "Covered outlets",
      "value": "Yes"
    },
    {
      "key": "co_shutdown",
      "label": "CO shutdown",
      "value": "Automatic CO shutdown present (CO Shield)"
    },
    {
      "key": "low_oil",
      "label": "Low-oil shutdown",
      "value": "Yes"
    },
    {
      "key": "overload",
      "label": "Overload protection",
      "value": "Yes"
    },
    {
      "key": "epa",
      "label": "EPA certified",
      "value": "Yes"
    },
    {
      "key": "pgma",
      "label": "PGMA compliant",
      "value": "Yes"
    },
    {
      "key": "weight_kg",
      "label": "Weight (dry)",
      "value": "99.5 kg (219.4 lb)"
    },
    {
      "key": "dimensions_mm",
      "label": "Dimensions (L × W × H)",
      "value": "730 × 698 × 662 mm"
    },
    {
      "key": "wheels",
      "label": "Wheel kit included",
      "value": "Yes"
    },
    {
      "key": "type",
      "label": "Type",
      "value": "Conventional (portable) · Open frame"
    },
    {
      "key": "watts_per_kg",
      "label": "Watts per kg",
      "value": "92.5 W/kg"
    },
    {
      "key": "runtime_per_gal",
      "label": "Runtime per gallon @ 50% load",
      "value": "1.2 h/gal"
    },
    {
      "key": "portability_band",
      "label": "Portability band",
      "value": "heavy"
    }
  ],
  "useCases": [
    "Home backup via a proper transfer switch: 120/240 V with L14-30R and 14-50R outlets",
    "Storm resilience with three fuel paths — including natural gas from a house line",
    "Jobsite power with GFCI-protected 120 V outlets",
    "Long outages: 10 h at 50% load per gasoline tank, indefinite on natural gas supply"
  ],
  "strengths": [
    "Tri-fuel with per-fuel watts officially published for all three fuels",
    "CO Shield auto-shutoff with PGMA G300 conformance",
    "GFCI 120 V outlets and covered receptacles",
    "Electric start with included battery; NG hose kit included",
    "3-year warranty with lifetime technical support"
  ],
  "weaknesses": [
    "The 14-50R outlet is rated 38 A by Champion, not a full 50 A",
    "No TT-30R — RV use requires adapters despite the 240 V outlets",
    "Noise figure lacks a load basis; no THD published (conventional unit)",
    "99.5 kg — wheeled, two-person lifts",
    "Official weight conflict between manual (219 lb) and page (216 lb)"
  ],
  "merchantLinks": [
    {
      "merchant": "Amazon",
      "url": "#",
      "note": "Affiliate link placeholder — not yet active"
    }
  ],
  "comparisons": [
    {
      "id": "high-output-dual-tri-fuel-home-backup",
      "title": "High-Output Dual & Tri-Fuel Home-Backup Generators: DuroMax XP13000EH vs Westinghouse iGen11000TFc vs WGen9500DF vs Champion 201412 vs DuroMax XP9000iH vs Firman WT05571",
      "canonicalUrl": "https://agentretrievalindex.com/comparisons/high-output-dual-tri-fuel-home-backup/",
      "jsonUrl": "https://agentretrievalindex.com/comparisons/high-output-dual-tri-fuel-home-backup.json"
    }
  ],
  "updatedAt": "2026-07-08"
}