Generator entity · Conventional (portable)
Champion 201412 Tri Fuel
Tri-fuel home-backup workhorse: 9,200 W running / 11,500 W starting on gasoline (8,500/10,625 W propane, 7,500/9,375 W natural gas), 120/240 V with L14-30R and 14-50R outlets, GFCI 120 V outlets, CO Shield shutdown, and 10 h at 50% load on the 8.5 gal tank.
Machine summary · generator · champion-201412
- brand
- Champion
- model_name
- 201412 (9200W Electric Start Tri Fuel with CO Shield)
- generator_type
- conventional_portable
- fuel
- gasoline+propane+natural_gas
- running_watts
- 9200
- starting_watts
- 11500
- voltage
- 120/240V
- co_shutdown
- present
- rv_outlet_present
- false
- weight_kg
- 99.5
- confidence_level
- medium
- source_last_checked
- 2026-07-08
- json_export
- /generators/champion-201412.json
Overview
Champion's 201412 runs on gasoline, propane, or natural gas — with per-fuel running and starting watts published in the manual's spec tables and stored separately here. Its 459 cc engine feeds a 120/240 V panel: an L14-30R locking outlet, a 14-50R that Champion rates at 38 A (not 50 A — worth knowing before buying a cord), and four GFCI-protected 120 V household outlets. Electric start with included battery, CO Shield automatic shutdown (whose manual explicitly notes it is not a substitute for an indoor CO alarm — and never permits indoor use), and a 25-ft natural gas hose kit in the box. Runtime: 10 h at 50% load on gasoline, 5 h at 50% on a 20-lb propane tank; natural gas runtime is supply-line dependent and unpublished. THD is not stated — this conventional AVR unit is not flagged for sensitive electronics.
Variant note: Selected as the best-documented 8,500 W+-class tri-fuel conventional with both L14-30R and 14-50R. Related tri-fuel models (separate entities): 201176 (9,000 W open-frame inverter), 201438 (10,000 W), 201161 (12,000 W with true 50 A 14-50R), 201241 (13,500 W), 201121 (8,000 W).
Data note: Weight conflict between official sources (manual '219 lb. (99.5 kg)' vs page '216 lb.'); manual value used, both preserved. Champion rates the 14-50R at 38 A — recorded exactly, since buyers assume 50 A from the receptacle form. Natural-gas runtime unpublished (supply-line dependent). THD not stated anywhere official; conventional AVR unit → sensitive-electronics suitability low. Noise (74 dBA from 23 ft) lacks a load basis → stored unknown_basis, noiseClass unknown. CARB and CSA/ETL not stated (null). Grounding: neutral bonded to frame. pgmaCompliant=true per PGMA G300-2018 reference in the manual.
Specifications
Running and starting watts are never collapsed; every runtime figure carries its fuel and load basis; THD is shown only when officially stated numerically. Core values' original claims and sources are in the provenance table. The final group is computed from the fields above and marked as derived.
| Attribute | Value |
|---|---|
| Running (rated) watts | 9,200 W |
| Starting (peak) watts | 11,500 W |
| Running watts by fuel | Gasoline: 9,200 W · Propane (LPG): 8,500 W · Natural gas: 7,500 W |
| Starting watts by fuel | Gasoline: 11,500 W · Propane (LPG): 10,625 W · Natural gas: 9,375 W |
| Voltage | 120/240V |
| Frequency | 60Hz |
| Total harmonic distortion | Not numerically stated |
| 240V support | Yes |
| Attribute | Value |
|---|---|
| Fuel | Gasoline + Propane (LPG) + Natural gas |
| Fuel tank (gasoline) | 8.5 gal |
| Runtime — Gasoline, 50% load | 10 h |
| Runtime — Propane (LPG), 50% load | 5 h |
| Fuel notes | Propane runtime (5 h at 50%) is on a 20-lb tank. Natural gas runtime not published; NG operation requires a dedicated supply line sized to the manual's minimum flow table (25-ft NG hose kit included). Noise: 74 dBA from 23 ft, load basis not stated. |
| Attribute | Value |
|---|---|
| Engine displacement | 459 cc |
| Noise | 74 dBA (load basis not stated) |
| Start method | recoil, electric |
| Parallel capable | No |
| Inverter technology | No |
| Attribute | Value |
|---|---|
| Receptacles | 4 × 5-20R (two GFCI duplexes (four outlets), 120V 20A), 1 × L14-30R (120/240V 30A locking), 1 × 14-50R (120/240V — rated 38A by Champion, not 50A) |
| RV outlet (30A RV receptacle) | No |
| TT-30R present | No |
| L14-30R present | Yes |
| GFCI outlets | Yes |
| Covered outlets | Yes |
| Attribute | Value |
|---|---|
| CO shutdown | Automatic CO shutdown present (CO Shield) |
| Low-oil shutdown | Yes |
| Overload protection | Yes |
| EPA certified | Yes |
| PGMA compliant | Yes |
| Attribute | Value |
|---|---|
| Weight (dry) | 99.5 kg (219.4 lb) |
| Dimensions (L × W × H) | 730 × 698 × 662 mm |
| Wheel kit included | Yes |
| Type | Conventional (portable) · Open frame |
| Attribute | Value |
|---|---|
| Watts per kg | 92.5 W/kg |
| Runtime per gallon @ 50% load | 1.2 h/gal |
| Portability band | heavy |
Use cases
- Home backup via a proper transfer switch: 120/240 V with L14-30R and 14-50R outlets
- Storm resilience with three fuel paths — including natural gas from a house line
- Jobsite power with GFCI-protected 120 V outlets
- Long outages: 10 h at 50% load per gasoline tank, indefinite on natural gas supply
Cross-category fit flags (stored for future battery-vs-generator pages, not yet used for ranking): RV not suitable · camping not suitable · home backup suitable · apartment use: no · sensitive electronics: low · noise class: unknown.
Strengths and weaknesses
Strengths
- Tri-fuel with per-fuel watts officially published for all three fuels
- CO Shield auto-shutoff with PGMA G300 conformance
- GFCI 120 V outlets and covered receptacles
- Electric start with included battery; NG hose kit included
- 3-year warranty with lifetime technical support
Weaknesses
- The 14-50R outlet is rated 38 A by Champion, not a full 50 A
- No TT-30R — RV use requires adapters despite the 240 V outlets
- Noise figure lacks a load basis; no THD published (conventional unit)
- 99.5 kg — wheeled, two-person lifts
- Official weight conflict between manual (219 lb) and page (216 lb)
Comparisons featuring this generator
High-Output Dual & Tri-Fuel Home-Backup Generators: DuroMax XP13000EH vs Westinghouse iGen11000TFc vs WGen9500DF vs Champion 201412 vs DuroMax XP9000iH vs Firman WT05571
Six high-output 120/240 V multi-fuel generators for whole-house backup through a transfer switch — 5,500–10,500 W running, dual- and tri-fuel, conventional and inverter. They separate on output, fuel flexibility, power quality (only the inverters offer clean THD), and one critical safety point: five have CO-shutdown, one documents that it does not.
Where to buy
Merchant links are scaffolded but not yet active. When live, some will be affiliate links; merchant relationships never affect indexed specifications or verdicts.
- Official product page: https://www.championpowerequipment.com/product/201412-9200w-electric-start-tri-fuel-generator-with-co-shield/
- Amazon: link pending — Affiliate link placeholder — not yet active
Sources and provenance
Core specifications — including all safety fields — come from official manufacturer sources only, with the exact claim text preserved per field. Safety-related fields carry the strictest rules: CO-shutdown status is never inferred from marketing. See the methodology for the full policy.
| Field | Normalized value | Raw claim | Source | Confidence |
|---|---|---|---|---|
runningWatts | 9200 | Watts (Starting/Running).............................. 11500/9200 | Official manual (PDF) — Gasoline figures; page matches. | high |
startingWatts | 11500 | Watts (Starting/Running).............................. 11500/9200 | Official manual (PDF) | high |
runningWattsByFuel | {"gasoline":9200,"propane":8500,"natural_gas":7500} | Watts (LPG) (Starting/Running)........................ 10625/8500 ... Watts (NG) (Starting/Running)........................... 9375/7500 | Official manual (PDF) — All three fuels numerically published in the manual spec table. | high |
startingWattsByFuel | {"gasoline":11500,"propane":10625,"natural_gas":9375} | Watts (LPG) (Starting/Running)........................ 10625/8500 ... Watts (NG) (Starting/Running)........................... 9375/7500 | Official manual (PDF) | high |
voltage | 120/240V | Volts AC...................................................... 120/240 ... Frequency ...................................................... 60 Hz | Official manual (PDF) — Gasoline AC amps: 76.7A @ 120V, 38.3A @ 240V per manual. | high |
receptacleSummary | {"5-20R":4,"L14-30R":1,"14-50R":1} | 120/240V AC, 30A Locking (NEMA L14-30R) ... 120/240V AC, 38A (NEMA 14-50R) ... (4x) 120V AC, 20A GFCI (NEMA 5-20R) | Official manual (PDF) — Champion rates the 14-50R at 38 A. No TT-30R → rvOutletPresent=false; no DC output. | high |
fuelTankCapacityGal | 8.5 | Gasoline Capacity................................... 8.5 gal. (31.9 L) | Official manual (PDF) | high |
runtimeAt50LoadHours | 10 | will run for 10 hours at 50% load when the 8.5-gallon fuel tank is full | Official product page — Propane: 5 h at 50% on a 20-lb tank — stored per-fuel. Natural gas runtime not published. No 25% figures. | high |
noiseDb | {"unknown_basis":74} | 74 dB(A) from 23 feet | Official product page — Distance stated but LOAD basis not — stored unknown_basis per policy; noiseClass unknown. | medium |
coShutdown | present | CO Shield® technology monitors the accumulation of carbon monoxide (CO)... If CO Shield® detects unsafe elevated levels of CO gas, it automatically shuts off the engine. | Official manual (PDF) — Manual also warns: 'CO SHIELD® IS NOT A SUBSTITUTE FOR AN INDOOR CARBON MONOXIDE ALARM OR FOR INDOOR OPERATION.' | high |
pgmaCompliant | true | PGMA G300-2018 | Official manual (PDF) — Standard reference recorded. | high |
weightKg | 99.5 | Weight.............................................. 219 lb. (99.5 kg) | Official manual (PDF) — CONFLICT: product page spec table lists '216 lb.' (98.0 kg). Manual value used; both preserved. Ships without oil. | medium |
dimensionsMm | {"l":730,"w":698,"h":662} | Length............ 28.7 in. (73.0 cm) / Width ............ 27.5 in. (69.8 cm) / Height............ 26.1 in. (66.2 cm) | Official manual (PDF) — Champion's own cm values ×10; page matches. | high |
engineSizeCc | 459 | Displacement................................................. 459 cc | Official manual (PDF) — Engine GB460T-2, 4-stroke OHV, 3,600 rpm. | high |
warrantyYears | 3 | CHAMPION POWER EQUIPMENT 3 YEAR LIMITED WARRANTY | Official manual (PDF) | high |
lowOilShutdown | true | This engine is equipped with a low oil shut-off and will stop when the oil level in the crankcase falls below the threshold level. | Official manual (PDF) | high |
totalHarmonicDistortion | — | Automatic Voltage Regulation: Yes | Official spec page — No THD stated anywhere official; conventional AVR unit — sensitive-electronics suitability set to low. | high |
All sources used
- https://www.championpowerequipment.com/product/201412-9200w-electric-start-tri-fuel-generator-with-co-shield/
- https://www.championpowerequipment.com/wp-content/uploads/2024/03/201412-om-english.pdf
- https://www.championpowerequipment.com/wp-content/uploads/2024/03/201412-om-english.pdf (official manual)